• DocumentCode
    473542
  • Title

    Aspects of sizing battery energy storage capacity for a Unified Power Flow Control scheme

  • Author

    Tan, Z.X. ; Choi, S.S.

  • Author_Institution
    Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore
  • fYear
    2007
  • fDate
    3-6 Dec. 2007
  • Firstpage
    1000
  • Lastpage
    1005
  • Abstract
    Incorporation of battery energy storage system into a Unified Power Flow Control (UPFC) scheme is examined. One crucial factor in the design is in the determination of the capacity of the storage system. Assuming the power input to the battery storage system is from a photovoltaic source, design issues including battery utilization factor and the state of charge of the battery are used in a method to determine and assess the suitability of battery capacity. A computational method to achieve the design is proposed.
  • Keywords
    battery storage plants; load flow control; battery energy storage capacity; battery utilization factor; photovoltaic source; state of charge; unified power flow control; Batteries; Energy storage; Load flow control; Power engineering; Battery energy storage system; Buffer; Lead acid battery; Solar Radiation; Unified Power-Flow Controller;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Conference, 2007. IPEC 2007. International
  • Conference_Location
    Singapore
  • Print_ISBN
    978-981-05-9423-7
  • Type

    conf

  • Filename
    4510171