• DocumentCode
    473997
  • Title

    Towards a THz osmometer

  • Author

    Zafiropoulos, Apostolos ; Hadjiloucas, Sillas ; Walker, Gillian C. ; Bowen, John W. ; Dudley, Richard

  • Author_Institution
    Cybern. Sch. of Syst. Eng., Reading Univ., Reading
  • fYear
    2007
  • fDate
    2-9 Sept. 2007
  • Firstpage
    295
  • Lastpage
    296
  • Abstract
    This work discusses the use of a THz-transient spectrometer for the measurement of tissue water content. The relation of both mammalian- and plant-cell water content to the osmotic potential is discussed. The process of equilibration of tissue water potential with the water potential of water vapor in an osmometer cuvette is described. Observation of the THz transmittance through the water vapor provides a measure of the water activity and water potential in the sample. The possibility of performing dielectric relaxation measurements of the liquid water in the tissue at THz frequencies directly and the use of proline as marker of water stress in tissue are discussed.
  • Keywords
    biological tissues; dielectric relaxation; osmosis; submillimetre wave devices; submillimetre wave spectroscopy; THz osmometer; THz-transient spectrometer; dielectric relaxation measurements; osmometer cuvette; osmotic potential; tissue water content measurement; tissue water stress; Absorption; Biological tissues; Chemicals; Infrared spectra; Phase measurement; Pulse measurements; Shape measurement; Spectroscopy; Time measurement; Ultrafast optics; humidity transducers; infrared spectroscopy; millimeter wave spectroscopy; ultrafast optics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Infrared and Millimeter Waves, 2007 and the 2007 15th International Conference on Terahertz Electronics. IRMMW-THz. Joint 32nd International Conference on
  • Conference_Location
    Cardiff
  • Print_ISBN
    978-1-4244-1438-3
  • Type

    conf

  • DOI
    10.1109/ICIMW.2007.4516505
  • Filename
    4516505