• DocumentCode
    474099
  • Title

    Detection of tulobuterol crystal in transdermal tapes using terahertz pulsed spectroscopy and imaging

  • Author

    Sakamoto, Tomoaki ; Portieri, Alessia ; Taday, Philip F. ; Sasakura, Daisuke ; Terahara, Takaaki ; Miura, Tsuyoshi ; Higo, Naruhito ; Arnone, Donald D. ; Hiyama, Yukio

  • Author_Institution
    Div. of Drugs, Nat. Inst. of Health Sci., Tokyo
  • fYear
    2007
  • fDate
    2-9 Sept. 2007
  • Firstpage
    569
  • Lastpage
    570
  • Abstract
    Applicability of the terahertz pulsed spectroscopy (TPS) and the terahertz pulsed imaging (TPI) to detect tulobuterol (TBR) crystal in transdermal tape has been investigated. The TBR crystal was identified by comparison between spectrum of tapes and TBR reference standard. The TBR crystal in patch matrix was successfully detected by the TPS and TPI. These results indicate that the TPS and TPI are applicable to identify an active substance in patch matrix for quality control.
  • Keywords
    patient diagnosis; skin; submillimetre wave imaging; submillimetre wave spectroscopy; patch matrix; quality control; terahertz pulsed imaging; terahertz pulsed spectroscopy; transdermal tapes; tulobuterol crystal detection; Chemical technology; Crystals; Optical imaging; Optical pulses; Pharmaceutical technology; Pulse measurements; Spatial resolution; Spectroscopy; Thickness measurement; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Infrared and Millimeter Waves, 2007 and the 2007 15th International Conference on Terahertz Electronics. IRMMW-THz. Joint 32nd International Conference on
  • Conference_Location
    Cardiff
  • Print_ISBN
    978-1-4244-1438-3
  • Type

    conf

  • DOI
    10.1109/ICIMW.2007.4516633
  • Filename
    4516633