DocumentCode
477279
Title
Compact high voltage subnanosecond pulsed power delivery system for biological applications
Author
Krishnaswamy, P. ; Kuthi, A. ; Chen, Meng-Tse ; Chen, Shih-Jui ; Vernier, P. Thomas ; Gundersen, M.A.
Author_Institution
Department of Electrical Engineering-Electrophysics, University of Southern California, Los Angeles, 90089-0271, USA
Volume
1
fYear
2007
fDate
17-22 June 2007
Firstpage
476
Lastpage
480
Abstract
Intracellular electro-manipulation experiments require subnanosecond high voltage pulses delivered to low impedance biological loads. We present here the design and construction of an experimental setup to deliver such subnanosecond high voltage pulses to biological cell solutions. This low-parasitic electronic setup interfaces our avalanche transistor-switched pulse generation system with the imaging and monitoring apparatuses used for bio-photonic studies of pulse-induced intracellular effects. The setup features a custom fabricated microscope slide to hold the cell solution under study, and a printed circuit board designed to carry the output pulse from the pulse generator to micro-machined electrodes on the glass slide. The pc-board and the slide are designed to match the load impedance of the pulse generator. This minimizes reflections back into the pulse generator, and minimizes distortion of pulse shape and pulse parameters. Further, the pc-board contains a custom-made high bandwidth voltage divider to allow for real-time monitoring of pulses delivered to the cell solution.
Keywords
Biological cells; Biophotonics; Impedance; Microscopy; Monitoring; Printed circuits; Pulse circuits; Pulse generation; Pulse shaping methods; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulsed Power Conference, 2007 16th IEEE International
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0913-6
Electronic_ISBN
978-1-4244-0914-3
Type
conf
DOI
10.1109/PPPS.2007.4651885
Filename
4651885
Link To Document