DocumentCode
482354
Title
3D thermal analysis of water cooling induction motor used for HEV
Author
Song, Liwei ; Li, Zijian ; Gao, Jingyi ; Zeng, Qingchu ; Wang, Fuping
Author_Institution
Res. Station on Mater. Sci. & Eng. for Postdoctoral Fellows, Harbin Inst. of Technol., Harbin
fYear
2008
fDate
17-20 Oct. 2008
Firstpage
534
Lastpage
537
Abstract
For water cooling induction motor used for HEV, transient and steady thermal analysis are useful to predict the temperature distribution, propose requirement on the water cooling system and enable designers to optimize the motor design. This paper adopts the approach of combining simulation and experiment to identify the time-dependent boundary conditions and heat sources in Ansys, proposes a 3D model for the calculation of transient and steady thermal analysis. A 30 kW prototype motor has been used to perform the test of temperature rise under rated load. The thermal analysis results are compared with experiment results to give valuable conclusions..
Keywords
cooling towers; induction motors; power system simulation; thermal analysis; 3D thermal analysis; HEV; power 30 kW; water cooling induction motor; Analytical models; Boundary conditions; Cooling; Design optimization; Hybrid electric vehicles; Induction motors; Performance evaluation; Prototypes; Temperature distribution; Transient analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
Conference_Location
Wuhan
Print_ISBN
978-1-4244-3826-6
Electronic_ISBN
978-7-5062-9221-4
Type
conf
Filename
4770758
Link To Document