Title : 
Limitations of using resistance measurements to qualify garments for use in EPA
         
        
        
            Author_Institution : 
Holdstock Tech. Services, Manchester, UK
         
        
        
        
        
        
            Abstract : 
The latest standards that define requirements for an effective ESD Control Program only make reference to point-to-point resistance measurements for qualifying garments that may be specified within such a program. Studies are reported that show that the surface voltage generated when rubbing fabrics does not relate to measured resistance.
         
        
            Keywords : 
clothing; electric resistance measurement; electrostatic discharge; fabrics; surface resistance; ESD; fabrics; garments; point-to-point resistance measurements; rubbing; surface voltage; Clothing; Conducting materials; Electrical resistance measurement; Electrodes; Electrostatic discharge; Fabrics; IEC standards; Measurement standards; Surface resistance; Yarn;
         
        
        
        
            Conference_Titel : 
Electrical Overstress/Electrostatic Discharge Symposium, 2008. EOS/ESD 2008. 30th
         
        
            Conference_Location : 
Tucson, AZ
         
        
            Print_ISBN : 
978-1-58537-146-4
         
        
            Electronic_ISBN : 
978-1-58537-147-1