Saturation of the Right-Leg Drive Amplifier in Low-Voltage ECG Monitors
Author :
Freeman, Daniel K. ; Gatzke, Ronald D. ; Mallas, Georgios ; Yu Chen ; Brouse, Chris J.
Author_Institution :
Dept. of Algorithms, Drager Med. Syst., Inc., Andover, MA, USA
Volume :
62
Issue :
1
fYear :
2015
fDate :
Jan. 2015
Firstpage :
323
Lastpage :
330
Abstract :
Electrocardiogram (ECG) monitoring is a critical tool in patient care, but its utility is often balanced with frustration from clinicians who are constantly distracted by false alarms. This has motivated the need to readdress the major factors that contribute to ECG noise with the goal of reducing false alarms. In this study, we describe a previously unreported phenomenon in which ECG noise can result from an unintended interaction between two systems: 1) the dc lead-off circuitry that is used to detect whether electrodes fall off the patient; and 2) the right-leg drive (RLD) system that is responsible for reducing ac common-mode noise that couples into the body. Using a circuit model to study this interaction, we found that in the presence of a dc lead-off system, even moderate increases in the right-leg skin-electrode resistance can cause the RLD amplifier to saturate. Such saturation can produce ECG noise because the RLD amplifier will no longer be capable of attenuating ac common-mode noise on the body. RLD saturation is particularly a problem for modern ECG monitors that use low-voltage supply levels. For example, for a 12-lead ECG and a 2 V power supply, saturation will occur when the right-leg electrode resistance reaches only 2 MΩ. We discuss several design solutions that can be used in low-voltage monitors to avoid RLD saturation.
Keywords :
amplifiers; biomedical electrodes; electrocardiography; patient care; patient monitoring; skin; ECG noise; RLD amplifier; RLD saturation; RLD system; ac common-mode noise; circuit model; dc lead-off circuitry; dc lead-off system; electrocardiogram monitoring; low-voltage ECG monitoring; patient care; right-leg drive amplifier; right-leg drive system; right-leg skin-electrode resistance; unintended interaction; Capacitance; Electrocardiography; Electrodes; Immune system; Impedance; Lead; Noise; Electrocardiogram (ECG); electrode impedance; lead-off; right-leg drive (RLD);
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2014.2351611
Filename :
6887342
Link To Document :
بازگشت