DocumentCode :
492144
Title :
Synthetic Aperture Beamformer for Pipeline Girth Weld Inspection
Author :
Ying-hua, Du ; Shi-jiu, JIN
Author_Institution :
State Key Lab. of Precision Meas. Technol. & Instrum., Tianjin Univ., Tianjin
fYear :
2008
fDate :
21-22 Dec. 2008
Firstpage :
407
Lastpage :
409
Abstract :
Synthetic aperture focusing technique (SAFT) has the advantage of high resolution, can be used in near-field and the ability of three-dimensional image formation. The focusing precision of the beamformer is the key factor that influencing the synthetic aperture imaging quality. A digital synthetic aperture beamformer is presented used in pipeline girth weld inspection, and the key points of FPGA implementation are also introduced. The testing results illustrate that this beamformer has good ultrasound formation ability, high lateral resolution and good performance.
Keywords :
array signal processing; field programmable gate arrays; inspection; pipelines; ultrasonic imaging; welding; focusing precision; lateral resolution; pipeline girth weld inspection; synthetic aperture beamformer; synthetic aperture focusing technique; synthetic aperture imaging quality; three-dimensional image formation; ultrasound formation; Delay; Field programmable gate arrays; Focusing; Image reconstruction; Image resolution; Inspection; Laboratories; Pipelines; Ultrasonic imaging; Welding; SAFT; beamformer; weld inspection;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Knowledge Acquisition and Modeling Workshop, 2008. KAM Workshop 2008. IEEE International Symposium on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-3530-2
Electronic_ISBN :
978-1-4244-3531-9
Type :
conf
DOI :
10.1109/KAMW.2008.4810510
Filename :
4810510
Link To Document :
بازگشت