• DocumentCode
    492327
  • Title

    Hydro generator stator cores part 2 - core losses, degradation mechanisms, testing and specification

  • Author

    Znidarich, M.M.

  • Author_Institution
    TGE Energy Services, Osborne Park, WA
  • fYear
    2008
  • fDate
    14-17 Dec. 2008
  • Firstpage
    1
  • Lastpage
    9
  • Abstract
    In the preceding paper hydro generator constructional features and causes of core losses were presented. This second paper will further cover the definition of stator core losses (open circuit and short circuit) and the way they are segregated for stator core loss calculations. Stator core insulation degradation mechanisms (thermal, mechanical and partial discharges) are described. The methodologies for stator core full ring flux test and reduced flux ELCID testing are briefly covered, followed by a summary of contemporary stator magnetic core material standards and specifications. Important factors relative to new/replacement hydro generator stator core specification are summarized at the conclusion of this paper.
  • Keywords
    hydroelectric generators; machine insulation; machine testing; magnetic cores; stators; contemporary stator magnetic core material standards; degradation mechanisms; hydro generator stator cores; reduced flux ELCID testing; stator core full ring flux test; stator core insulation; stator core losses; Circuits; Core loss; Degradation; Frequency; Iron; Magnetic materials; Stator cores; Stator windings; Teeth; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Conference, 2008. AUPEC '08. Australasian Universities
  • Conference_Location
    Sydney, NSW
  • Print_ISBN
    978-0-7334-2715-2
  • Electronic_ISBN
    978-1-4244-4162-4
  • Type

    conf

  • Filename
    4812987