Abstract
In the preceding paper hydro generator constructional features and causes of core losses were presented. This second paper will further cover the definition of stator core losses (open circuit and short circuit) and the way they are segregated for stator core loss calculations. Stator core insulation degradation mechanisms (thermal, mechanical and partial discharges) are described. The methodologies for stator core full ring flux test and reduced flux ELCID testing are briefly covered, followed by a summary of contemporary stator magnetic core material standards and specifications. Important factors relative to new/replacement hydro generator stator core specification are summarized at the conclusion of this paper.
Keywords
hydroelectric generators; machine insulation; machine testing; magnetic cores; stators; contemporary stator magnetic core material standards; degradation mechanisms; hydro generator stator cores; reduced flux ELCID testing; stator core full ring flux test; stator core insulation; stator core losses; Circuits; Core loss; Degradation; Frequency; Iron; Magnetic materials; Stator cores; Stator windings; Teeth; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Conference, 2008. AUPEC '08. Australasian Universities
Conference_Location
Sydney, NSW
Print_ISBN
978-0-7334-2715-2
Electronic_ISBN
978-1-4244-4162-4
Type
conf
Filename
4812987
Link To Document