    The interaction of transient electromagnetic field due to an NEMP with buried cables has been studied in this paper. The cables studied were of two types: shielded as well as unshielded cables. Using transmission line analysis, the induced voltage and current are computed at the load end of the cable for different soil conductivities, different depths of burial of cable and for different lengths of the cable. Effect of shielding on the induced voltage on the cable inner conductor as well as the dependence of the induced voltage on the shield thickness are also studied.
  • Keywords
    cable shielding; electromagnetic coupling; electromagnetic fields; electromagnetic shielding; buried shielded cables; induced current; induced voltage; shielding effect; soil conductivities; transient NEMP field coupling; transient electromagnetic field; transmission line analysis; unshielded cables; Cable shielding; Cables; Conductivity; Couplings; Electromagnetic fields; Electromagnetic transients; Power system transients; Soil; Transmission lines; Voltage;