• DocumentCode
    495393
  • Title

    Analyze and Improve the Time Synchronization in EPA

  • Author

    Shang, Qunli ; Jiang, Rongjin ; Yu, Shan-en

  • Author_Institution
    Coll. of Autom., Hangzhou Dianzi Univ., Hangzhou, China
  • Volume
    3
  • fYear
    2009
  • fDate
    March 31 2009-April 2 2009
  • Firstpage
    156
  • Lastpage
    161
  • Abstract
    In order to improve the time synchronization precision to insure the communication timely, several types of clock synchronization methods were compared, analyzed the IEEE1588 clock synchronization system, discussed the PTP system software programming, introduced some source code transplanting methods, got the root cause of the low precision, provided three major improving methods, tested the improved system, the results indicate the high precision time synchronization has been attained.
  • Keywords
    industrial control; local area networks; protocols; synchronisation; EPA; Ethernet; IEEE 1588 clock synchronization system; PTP system software programming; industrial control; precision time protocol; source code transplanting method; time synchronization; Automation; Clocks; Communication system control; Electrical equipment industry; Ethernet networks; Industrial control; Information analysis; Standards organizations; Standards publication; Synchronization; IEEE1588; clock synchronization; industrial Ethernet; one way delay; time offset;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Science and Information Engineering, 2009 WRI World Congress on
  • Conference_Location
    Los Angeles, CA
  • Print_ISBN
    978-0-7695-3507-4
  • Type

    conf

  • DOI
    10.1109/CSIE.2009.671
  • Filename
    5170821