DocumentCode
497257
Title
Study on Surface Treatment of Double Grid Air Counter Sensor
Author
Yuan Xiao-qing ; Shi Yi-kai
Author_Institution
Sch. of Mechatron., Northwestern Polytech. Univ., Xi´an, China
Volume
1
fYear
2009
fDate
11-12 April 2009
Firstpage
59
Lastpage
61
Abstract
In order to detect the microcrack of metal materials, a novel double grid air counter sensor was introduced. Starting with emission mechanism of low energy, ionic motion situation in the Double Grid Air Counter (DGAC) was analyzed, secondary electron emission was discussed, interaction between ion and inner wall of the counter and its effect on the counter was put forward, and treatment simulation graphs of counter inner surface plating different metals were given. The results showed that the counter plating gold could inhibit secondary electron and work accurately.
Keywords
crack detection; exoelectron emission; microcracks; sensors; surface cracks; surface treatment; counter inner surface plating; double grid air counter sensor; ionic motion situation; metal materials; microcrack detect; secondary electron emission; surface treatment; treatment simulation graphs; Anodes; Automation; Counting circuits; Electron emission; Energy loss; Gold; Inorganic materials; Lattices; Mechatronics; Surface treatment;
fLanguage
English
Publisher
ieee
Conference_Titel
Measuring Technology and Mechatronics Automation, 2009. ICMTMA '09. International Conference on
Conference_Location
Zhangjiajie, Hunan
Print_ISBN
978-0-7695-3583-8
Type
conf
DOI
10.1109/ICMTMA.2009.326
Filename
5202913
Link To Document