DocumentCode
503370
Title
A well-posed mathematical model of radiometer and its experimental embodiment with noise heterodyne
Author
Sergienko, S.P.
Author_Institution
Donetsk Nat. Univ., Donetsk, Ukraine
fYear
2009
fDate
14-18 Sept. 2009
Firstpage
801
Lastpage
802
Abstract
A well-posed mathematical model of a radiometer with noise and monochromatic heterodynes is proposed. It is shown that a radiometer with a noise heterodyne operates more effectively than a radiometer with monochromatic heterodyne. A prototype of a radiometer is designed and built, which allows using a noise source as well as a sinusoidal source as heterodyne. The operative embodiment of a radiometer demonstrated an increase of sensitivity by 30 dB using a noise heterodyne.
Keywords
noise; radiometers; experimental embodiment; monochromatic heterodyne; noise heterodyne; radiometer; sinusoidal source; well-posed mathematical model; Mathematical model; Radiometry; Tellurium; Zinc;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave & Telecommunication Technology, 2009. CriMiCo 2009. 19th International Crimean Conference
Conference_Location
Sevastopol
Print_ISBN
978-1-4244-4796-1
Type
conf
Filename
5292866