DocumentCode
504823
Title
Applying user monitoring for display power management
Author
Moshnyaga, Vasily G. ; Hasimoto, Koji ; Suetsugu, Tadashi
Author_Institution
Dept. of Electron. Eng. & Comput. Sci., Fukuoka Univ., Fukuoka, Japan
fYear
2009
fDate
18-21 Aug. 2009
Firstpage
3599
Lastpage
3604
Abstract
This paper discusses a new technology for reducing energy of computer display. Unlike existing power management schemes, which link the display operation to a key press or movement of the mouse, we use vision sensor to bind the display power state to the actual user´s attention. The technology tracks the user´s eyes, keeping the display active only if the user looks at the screen. Otherwise it dims the display down or even switches it off to save energy. We implemented the technology in hardware and present the results of their experimental evaluation.
Keywords
computer displays; image sensors; man-machine systems; computer display; display power management; display power state; energy reduction; man-machine system; user monitoring; vision sensor; CMOS technology; Cameras; Computer displays; Computerized monitoring; Energy management; Flowcharts; Hardware; Keyboards; Mice; Technology management; Embedded Systems; Emerging Technologies; Man-Machine Systems; System and Information;
fLanguage
English
Publisher
ieee
Conference_Titel
ICCAS-SICE, 2009
Conference_Location
Fukuoka
Print_ISBN
978-4-907764-34-0
Electronic_ISBN
978-4-907764-33-3
Type
conf
Filename
5334752
Link To Document