DocumentCode
504970
Title
Development of a compact-size and wireless surface EMG measurement system
Author
Youn, Wonkeun ; Kim, Jung
Author_Institution
Sch. of Mech. Aerosp. & Syst. Eng. Div. of Mech. Eng., KAIST, Daejeon, South Korea
fYear
2009
fDate
18-21 Aug. 2009
Firstpage
1625
Lastpage
1628
Abstract
This paper proposes a compact-size and a wireless surface EMG(electromyography) measurement system of a noninvasive type. The limitations of the current EMG sensor system include its large size, and the necessity of a wire. Therefore, this study focused on the development of a compact size preamplifier and wireless EMG measurement system. The EMG described herein is comprised of a preamplifier including an electrode for the measurement of the EMG signal, a main amplifier for signal processing, DSP(digital signal processor) processor for A/D conversion and digital signal processing, and a Bluetooth module for wireless communication. EMG signal obtained by the developed system results in better signal-to-noise ratio (SNR) compared to commercially available EMG system. This SNR of the developed system can be attributed to repeated signal processing on analog circuit and DSP, which reduces the size of the developed system. In our power spectral density, the EMG signal was distributed between approximately 20 Hz and 400 Hz. A Compact size and wireless surface EMG measurement system with high SNR can be useful for providing subjects comfort and consequently controlling external prosthesis.
Keywords
Bluetooth; analogue-digital conversion; biomedical measurement; electrodes; electromyography; medical signal processing; preamplifiers; sensors; A-D conversion; Bluetooth module; DSP processor; EMG signal measurement; analog circuit; compact size preamplifier; compact-size EMG measurement system; current EMG sensor system; digital signal processing; digital signal processor; electrode; electromyography; noninvasive-type measurement system; power spectral density; prosthesis; signal processing; signal-to-noise ratio; wireless communication; wireless surface EMG measurement system; Bluetooth; Digital signal processing; Electrodes; Electromyography; Preamplifiers; Sensor systems; Signal processing; Size measurement; Wire; Wireless sensor networks; Bluetooth module; EMG; Noninvasive; Wireless;
fLanguage
English
Publisher
ieee
Conference_Titel
ICCAS-SICE, 2009
Conference_Location
Fukuoka
Print_ISBN
978-4-907764-34-0
Electronic_ISBN
978-4-907764-33-3
Type
conf
Filename
5335070
Link To Document