Abstract :
X-ray CT is for nondestructive inspection in industrial field. In X-ray CT inspection, the problem is called ldquometal artifactrdquo on the reconstructed image is one of the biggest issue. This study aims to reduce metal artifact. Metal artifact is caused primarily by missing projection data from every projection angle. So, we propose the algorithm for correcting the missing projection data and confirm availability for nondestructive inspection in industrial field.
Keywords :
computerised tomography; image reconstruction; production engineering computing; X-ray CT inspection algorithm; image reconstruction; metal artifact; missing data correction; nondestructive inspection; Attenuation; Computed tomography; Detectors; Fourier series; Image reconstruction; Inspection; Metals industry; Physics; Production facilities; Reconstruction algorithms; 3D reconstruction; Feldkamp algorithm; X ray computed tomography;