DocumentCode
507899
Title
The Energy-Saving Design Practices for Direct Cooling Refrigerator
Author
Cai, Y.L. ; Zhang, Haijun ; Chen, S. ; Li, Guolin ; Xia, Peter
Author_Institution
Sch. of Energy & Power Eng., Univ. of Shanghai for Sci. & Technol., Shanghai, China
Volume
1
fYear
2009
fDate
16-18 Oct. 2009
Firstpage
411
Lastpage
414
Abstract
The area of evaporator on cold storage chamber was added under a constant total evaporator area. Composite and stereoscopic structure with laminated exchanger flake was used on evaporator of freezing chamber. Wing - flakes were fixed outside the refrigerant pipe coil with a S-type to increase the refrigeration capacity of the top part and the bottom part of freezing chamber. The refrigeration cycle of double path was adopted on project study. By the optimizing design of the condenser structure and circling - gas exchanger , direction and position of anti - condensation pipe and evaporator pipe, by matching the load of compressor, condenser and evaporator , a new type of direct cooling refrigerator was recently developed. It consumes 0.39 kWh per day under the maximum load.
Keywords
energy conservation; freezing; refrigerators; cold storage chamber; direct cooling refrigerator; energy-saving design; evaporator; freezing chamber; laminated exchanger flake; refrigerant pipe coil; refrigeration capacity; stereoscopic structure; Coils; Cooling; Design engineering; Design optimization; Energy consumption; Heat transfer; Power engineering and energy; Refrigerants; Refrigeration; Temperature; condensor; energy-saving; evaporator; refrigerantion;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy and Environment Technology, 2009. ICEET '09. International Conference on
Conference_Location
Guilin, Guangxi
Print_ISBN
978-0-7695-3819-8
Type
conf
DOI
10.1109/ICEET.2009.106
Filename
5363831
Link To Document