DocumentCode :
510586
Title :
Triangle mesh based 2D fluorescence molecular tomography with spatially smoothed linear scheme
Author :
Wang, Daifa ; Bai, Jing
Author_Institution :
Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
fYear :
2009
fDate :
2-6 Nov. 2009
Firstpage :
1
Lastpage :
2
Abstract :
In 2D fluorescence molecular tomography, there are usually discontinuities in the reconstructed image of continuous targets when using triangle mesh for discretization. A spatially smoothed linear scheme is proposed to overcome the limit. The phantom experiment on a full angle imaging system demonstrates the efficiency the proposed method.
Keywords :
Animals; Fluorescence; Geometry; Image reconstruction; Imaging phantoms; Linear systems; Luminescence; Reconstruction algorithms; Spectroscopy; Tomography;