• DocumentCode
    517438
  • Title

    EMI evaluation in hard switching and soft switching PWM flyback converters

  • Author

    Emami, Z. ; Farzanefard, H. ; Motahari, S.R.

  • Author_Institution
    Isfahan University of Technology/Department of Electrical & Computer Engineering, Iran
  • fYear
    2010
  • fDate
    17-18 Feb. 2010
  • Firstpage
    46
  • Lastpage
    51
  • Abstract
    Electromagnetic interference generally exists in all electrical and electronic equipment, especially in switching converters. Since the switching frequency applied in switching converter is high it can causes significant EMI. An experimental comparison of the EMI profiles of two flyback converters, operating under hard switching and soft switching is provided in this paper. Results indicate that EMI emission can be substantially reduced by using soft-switching technique in power converters.
  • Keywords
    Delta modulation; Electromagnetic interference; Frequency domain analysis; Frequency measurement; Noise measurement; Particle separators; Pulse width modulation; Pulse width modulation converters; Switching converters; Time measurement; EMI; Hard Switching; Soft Switching; ZVT flyback;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronic & Drive Systems & Technologies Conference (PEDSTC), 2010 1st
  • Conference_Location
    Tehran, Iran
  • Print_ISBN
    978-1-4244-5944-5
  • Type

    conf

  • DOI
    10.1109/PEDSTC.2010.5471857
  • Filename
    5471857