• DocumentCode
    517803
  • Title

    Tremor compensation by use of a mechatronic cup holder

  • Author

    Fischer, M. ; Schraufstetter, M. ; Richter, C. ; Irlinger, F. ; Lueth, T.C.

  • Author_Institution
    Dept. Micro Technol. & Med. Device Technol., Tech. Univ. Munchen, Munich, Germany
  • fYear
    2010
  • fDate
    22-25 March 2010
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    In this paper a new assistive device for persons suffering tremor disease is presented. It should help those people to get along with the everyday life situation of consuming beverages and replace the feeding cups currently used. The cup holder is built up as a mechatronic system. It consists of a kinematic structure sustaining a standard cup as well as electronic and software components. The cup is moved by the device in order to compensate linear and rotational accelerations as well as tilt induced by a person´s tremor. For this purpose the characteristics of the fast and large scaled tremor movements of the patient´s hand are measured first. By use of the inverse kinematics calculated for the system and a method for the modelling of the liquid´s movement, necessary reactions of the cup holder are deduced. Using this information the device´s motors are actuated to avoid spillage of the liquid. The underlying calculations are run on a micro controller integrated in the system. An experiment was conducted to validate the function of the system. For this purpose an industrial robot was used to apply common tremor frequencies and amplitudes to the cup holder. It was shown that by use of the compensatory cup holder the spillage of the beverage can be eliminated at a wide range of different tremors.
  • Keywords
    compensation; diseases; handicapped aids; industrial robots; mechatronics; microcontrollers; patient care; robot kinematics; assistive device; compensatory cup holder; industrial robot; inverse kinematics; kinematic structure; linear acceleration; liquid spillage; mechatronic cup holder; mechatronic system; microcontroller; rotational accelerations; tremor compensation; tremor disease; tremor frequency; tremor movements; Acceleration; Actuators; Control systems; Electrical equipment industry; Frequency; Humans; Kinematics; Mechatronics; Parkinson´s disease; Springs; assistive device; compensation; cup holder; mechatronic; tremor disease;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pervasive Computing Technologies for Healthcare (PervasiveHealth), 2010 4th International Conference on-NO PERMISSIONS
  • Conference_Location
    Munich
  • Print_ISBN
    978-963-9799-89-9
  • Electronic_ISBN
    978-963-9799-89-9
  • Type

    conf

  • DOI
    10.4108/ICST.PERVASIVEHEALTH2010.8885
  • Filename
    5482276