• DocumentCode
    519835
  • Title

    Low-frequency characterization of lossy material

  • Author

    Müller, Johannes ; Jacob, Arne F.

  • Author_Institution
    Inst. fur Hochfrequenztech., Tech. Univ. Hamburg-Harburg, Hamburg, Germany
  • fYear
    2010
  • fDate
    15-17 March 2010
  • Firstpage
    190
  • Lastpage
    193
  • Abstract
    The challenging characterization of very lossy materials at low frequencies is investigated by means of a coaxial sensor. The sensitivity of the sensor is analyzed and optimized for lossy materials. Systematic error sources are successfully identified and eliminated by means of a redundant calibration using a partly known reference material. The lower frequency range of the sensor is thereby extended to frequencies below 50 MHz. Owing to the novel calibration the measurement results reliably show little fluctuation.
  • Keywords
    absorbing media; microwave detectors; coaxial sensor; lossy material; low-frequency characterization; sensor sensitivity; systematic error sources; Calibration; Coaxial cables; Coaxial components; Conducting materials; Dielectric materials; Frequency; Microwave sensors; Permittivity measurement; Sensor phenomena and characterization; Waveguide junctions;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 2010 German
  • Conference_Location
    Berlin
  • Print_ISBN
    978-1-4244-4933-0
  • Electronic_ISBN
    978-3-9812668-1-8
  • Type

    conf

  • Filename
    5498309