Impact of the Local Oscillator Calibration Rate on the SMOS Measurements and Retrieved Salinities
Author
Gabarro, Carolina ; Gonzalez-Gambau, V. ; Corbella, I. ; Torres, F. ; Martinez, Jose Luis ; Portabella, Marcos ; Font, Jordi
Author_Institution
Inst. de Cienc. del Mar, Barcelona, Spain
Volume
51
Issue
9
fYear
2013
fDate
Sept. 2013
Firstpage
4633
Lastpage
4642
Abstract
The local oscillators (LOs) of the Soil Moisture and Ocean Salinity mission payload are used to shift the operating frequency of the 72 receivers to an optimal intermediate frequency needed for the signal processing. The LO temperature variations produce phase errors in the visibility, which result in a blurring of the reconstructed brightness temperature (Tb) image. At the end of the commissioning phase, it was decided to calibrate the LO every 10 min while waiting for a more in-depth analysis. During short periods of time, the LO calibration has been performed every 2 min to assess the impact of a higher calibration rate on the quality of the data. In this paper, by means of a decimation experiment, the relative errors of 6- and 10-min calibration interval data sets are estimated using the 2 min as a reference. A noticeable systematic across- and along-track pattern of amplitude ±0.3 K is observed for Tb differences between 10 and 2 min, whereas this is reduced between 6 and 2 min. A simulation experiment confirms that the nature of such systematic pattern is due to the visibility phase errors induced by the LO calibration rate. Such pattern is propagated into the sea surface salinity (SSS) retrievals. Overall, the SSS error increase (relative to the 2 min SSS data) is about 0.39 and 0.14 psu for the 10- and 6-min data sets, respectively. This paper shows that a LO calibration rate of at least 6 min would noticeably improve the SSS retrievals.
Keywords
calibration; ocean temperature; oceanographic techniques; LO calibration; LO calibration rate; SMOS Measurements; along-track pattern; calibration interval data sets; commissioning phase; local oscillator calibration rate; ocean salinity mission payload; reconstructed brightness temperature image; retrieved salinities; sea surface salinity; soil moisture; systematic pattern; Calibration; Noise; Receivers; Sea measurements; Temperature measurement; Thermal noise; Brightness temperature; Microwave Imaging Radiometer by Aperture Synthesis (MIRAS); Soil Moisture and Ocean Salinity (SMOS); calibration; interferometry; radiometer; salinity;
fLanguage
English
Journal_Title
Geoscience and Remote Sensing, IEEE Transactions on
Publisher
ieee
ISSN
0196-2892
Type
jour
DOI
10.1109/TGRS.2012.2233744
Filename
6459580
Link To Document