DocumentCode
523240
Title
Level and pressure control in condenser of the 13C isotope separation column
Author
Festila, Cl ; Dulf, E.H. ; Baldea, A.
Author_Institution
Dept. of Autom. Control, Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania
Volume
1
fYear
2010
fDate
28-30 May 2010
Firstpage
1
Lastpage
6
Abstract
The process of the 13C in cryogenic separation column is an intricate one. A lot of parameters must be kept constant at empirical values. From among these, the nitrogen level and the temperature in condenser are essential for the separation process. In present, the liquid nitrogen level is controlled manually and any error of the operators can waste the final product. The paper proposes not only a system for liquid nitrogen level control, but also a second system able to decrease - due to the under-pressure - the evaporation temperature of liquid nitrogen in order to improve the separation process. The paper analyzes the two systems as independent entities and the interinfluences are treated as disturbances. The analysis in the true MIMO frame is a future task.
Keywords
chemical industry; level control; pressure control; separation; 13C isotope separation column; MIMO frame; condenser temperature; cryogenic separation column; liquid nitrogen level control; pressure control; Boilers; Control systems; Cryogenics; Isotopes; Nitrogen; Pressure control; Research and development; Separation processes; Temperature control; Valves;
fLanguage
English
Publisher
ieee
Conference_Titel
Automation Quality and Testing Robotics (AQTR), 2010 IEEE International Conference on
Conference_Location
Cluj-Napoca
Print_ISBN
978-1-4244-6724-2
Type
conf
DOI
10.1109/AQTR.2010.5520904
Filename