DocumentCode
523283
Title
Affect of operation conditions of triple half bridge series resonant inverter for harmonic distortion and power factor
Author
Sazak, Bekir Sami ; Cetin, Sevilay
Author_Institution
Dept. of Electron. Educ., Pamukkale Univ., Denizli, Turkey
fYear
2010
fDate
2-4 June 2010
Firstpage
18
Lastpage
20
Abstract
The main aim of this paper is to discusses the change in harmonic distortion and power factor by the variation of operation conditions of a triple half bridge series resonant inverter circuit (THB-SRI). THB-SRI topology allows the control of three outputs, simultaneously and independently, up to their rated powers saving component count compared with the three half bridge solution. Results of this study can be used as an aid in component selection and understanding the affect of operation conditions to the other circuit parameters. Details of the study are presented along with simulation results.
Keywords
harmonic distortion; power factor; resonant invertors; THB-SRI topology; harmonic distortion; power factor; power saving component; triple half bridge series resonant inverter circuit; Bridge circuits; Circuit topology; Coils; Frequency; Harmonic distortion; Power generation; Reactive power; Resonant inverters; Switches; Switching circuits; Induction heating; PSpice; Power factor; THD;
fLanguage
English
Publisher
ieee
Conference_Titel
MECHATRONIKA, 2010 13th International Symposium
Conference_Location
Trencianske Teplice
Print_ISBN
978-1-4244-7962-7
Electronic_ISBN
978-80-8075-451-8
Type
conf
Filename
5521189
Link To Document