Title :
Effect of humidity on negative corona discharge of electrostatic precipitators
Author :
Xiaohua Wang ; Changfu You
Author_Institution :
Dept. of Thermal Eng., Tsinghua Univ., Beijing, China
Abstract :
The effect of humidity on the negative corona discharge of electrostatic precipitators was experimentally and numerically studied. The current-voltage characteristics of a wire-plate electrostatic precipitator was measured over a range of temperatures and relative humidities. The inception voltage and electric field were determined based on the streamer theory. A numerical method was used to study the influence of humidity on the distributions of electric field and charge density in an electrostatic precipitator. The results showed that the inception voltage and electric field decreased with the increase of humidity. The corona current was significantly affected by the humidity. A modified Peek formula was proposed with a correction to the humidity. The corona currents calculated with the modified Peek formula were in acceptable agreement with the experimental results. The distributions of electric field and charge density were affected by the humidity and applied voltage.
Keywords :
corona; electrostatic precipitators; glow discharges; humidity; numerical analysis; Peek formula; electrostatic precipitators; humidity; inception voltage; negative corona discharge; numerical method; streamer theory; Corona; Discharges (electric); Electric fields; Humidity; Mathematical model; Temperature; Wires; Peek formula; corona inception electric field; electrostatic precipitators; humidity;
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
DOI :
10.1109/TDEI.2013.6633702