• DocumentCode
    530733
  • Title

    A new type of temperature measurement system based on AOD sub-lance

  • Author

    Ge-Hua, Chen

  • Author_Institution
    Changchun Univ. Of Technol., Changchun, China
  • Volume
    3
  • fYear
    2010
  • fDate
    24-26 Aug. 2010
  • Firstpage
    396
  • Lastpage
    399
  • Abstract
    This study develops a new type AOD converter temperature measurement system. We transmitted light ray by the gas path of sub-lance without additional optical unit. This system introduced two-color near-infrared non-contact measurement. It eliminated errors caused by dusts or any other interfering factor. This system improves the temperature measurement accuracy greatly, and calculates the end point temperature based on carbon and chromium content required by the end point. The real-time temperature measurement could better control the smelting process and improve the hit rate at the end point.
  • Keywords
    carbon; chromium; furnaces; smelting; steel; temperature measurement; AOD converter temperature measurement system; AOD sublance; argon oxygen decarburization; carbon content; chromium content; end point temperature; liquid steel; smelting process; smelting process control; two color near infrared noncontact measurement; Carbon; Converters; AOD converter; dual wavelength; end point; near-infrared;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer, Mechatronics, Control and Electronic Engineering (CMCE), 2010 International Conference on
  • Conference_Location
    Changchun
  • Print_ISBN
    978-1-4244-7957-3
  • Type

    conf

  • DOI
    10.1109/CMCE.2010.5610297
  • Filename