DocumentCode :
531117
Title :
Bio-radiolocation method at chest wall motion analysis during tidal breathing
Author :
Korchagina, D.A. ; Alekhin, M.D. ; Anishchenko, L.N.
Author_Institution :
Bauman Moscow State Tech. Univ., Moscow, Russia
fYear :
2010
fDate :
Sept. 30 2010-Oct. 1 2010
Firstpage :
475
Lastpage :
478
Abstract :
Influence of chest wall surface motion in bio-radar signal during tidal breathing was researched. A high-speed camera and multi-frequency radar with signal step modulation were simultaneously applied. The model of chest motion during quite breathing was used. Pairwise correlation coefficients for all the markers on the chest wall given in the model were calculated. The correlation of data from high-speed camera and bio-radar was found. Two methods were compared.
Keywords :
correlation methods; pneumodynamics; radar applications; bioradiolocation method; chest wall motion analysis; high-speed camera; multifrequency radar; pairwise correlation coefficients; signal step modulation; tidal breathing; Cameras; Correlation; Data processing; Humans; Modulation; Radar remote sensing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Radar Conference (EuRAD), 2010 European
Conference_Location :
Paris
Print_ISBN :
978-1-4244-7234-5
Type :
conf
Filename :
5614951
Link To Document :
بازگشت