    Characterization of Optical Coherence Tomography Images Acquired at Large Distances With Large-Diameter Beams

  • Author

    Popescu, Dan P. ; Smith, Michael S. D. ; Sowa, Michael G.

  • Author_Institution
    Med. Devices Portfolio, Nat. Res. Council of Canada, Winnipeg, MB, Canada
  • Volume
    6
  • Issue
    3
  • fYear
    2014
  • fDate
    Jun-14
  • Firstpage
    1
  • Lastpage
    11
  • Abstract
    We tested the imaging capabilities for variants of a 1550-nm swept-source fiber-based optical coherence tomography system with a telecentric system incorporated at the end of its sample arm. The system was designed for in vivo imaging of burns; therefore, we acquired images from samples located at distances greater than 24 cm from the exit of the telecentric system. Each system variation had a specific combination of diameters for the reference and sample beams. In the reference arm, we used, alternately, two collimated beams with diameters of 1.5 and 14 mm, respectively. In the sample arm, we tested collimated beams with the following diameters: 1.5, 3.5, 5.7, 8.4, and 14 mm. A galvanometric mirror system scanned the collimated sample beam across the entrance pupil of the telecentric system. The sample beam exited the telecentric system parallel with its optical axis and convergent onto the sample. Depending on the collimator used in the sample arm, images were acquired with beams focused to waist diameters ranging from 40 to 240 μm. We acquired images with the sample at different locations within a ±30 mm range centered about the sample beam waist. Furthermore, we used the signal-to-noise ratio, the detected signal intensity, and the visual appearance to compare images acquired with different sample/reference beam configurations.
  • Keywords
    image processing; optical collimators; optical fibres; optical tomography; collimated beams; distance 1550 nm; galvanometric mirror system; in vivo imaging; large-diameter beams; optical coherence tomography images; reference arm; signal-to-noise ratio; size 1.5 mm to 14 mm; telecentric system; Biomedical optical imaging; Coherence; Collimators; Optical fibers; Optical imaging; Optical variables measurement; Optical coherence tomography; image analysis; medical optics instrumentation; speckle;
  • fLanguage
    English
  • Journal_Title
    Photonics Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1943-0655
  • Type

    jour

  • DOI
    10.1109/JPHOT.2014.2321754
  • Filename
    6815693