• DocumentCode
    533033
  • Title

    Notice of Retraction
    Improve the predetermined dose precision of electromagnetic pump with removable metal probe

  • Author

    Hou Jibo ; Liu Yun

  • Author_Institution
    Coll. of Mater. Sci. & Eng., North Univ. of China, Taiyuan, China
  • Volume
    13
  • fYear
    2010
  • fDate
    22-24 Oct. 2010
  • Abstract
    Notice of Retraction

    After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.

    We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.

    The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.

    With the development of modern casting technology, the precision and stability of predetermined dose irrigating system is required to satisfy the need for manufacturing high quality and high efficiency casting, yet now the front rationed feed liquid technology of aluminum alloy fluid furnace is not matured. In this paper, based on the mechanism of predetermined dose irrigating system in electromagnetic pump (EMP), the experiment and theory investigation with the Conservation Parameter Method (when the electromagnetic pump works, feed current is parameter), Cubage Compensation Method (with the molten aluminum alloy feeding in the casting model, feed current is adjusted by calculation the consumption in furnace) and Fixed Suspended Height Method (no need to confirm the remainder in furnace, feed current is adjusted by suspending the molten aluminum alloy on fixed position) is carried out. It´s found that the Fixed Suspended Height Method is the best for not conversion output condition. After then, the fixed metal probe, ceramic probe and removable metal probe are utilized to determine the suspended height. By the experiment to research the influence factor for the precision and stability of predetermined dose irrigating system, it is found that the removable probe can improve the fix quantity precision greatly, because of the metal probe is eroded easily when it is immersed in molten aluminum alloy frequently, and the ceramic probe looses connection for skin-deep oxygenic film. The removable probe can prevent corr- ding for the contact time is very short. We also found that besides the influence of suspended height, the predetermined dose irrigating precision is also affected by the hydrogen content in molten aluminum alloy, the oxidation impurity content and the power stability etc. Finally, the influence aspects to the predetermined dose irrigating precision and stability for the aluminum alloy electromagnetic pump are investigated and the improvement methods are d- termined. The method is the new direction for electromagnetic pump applying Aluminum Alloy Predetermined Dose Irrigating.
  • Keywords
    aluminium alloys; casting; ceramics; corrosion protection; liquid metals; pumps; aluminum alloy fluid furnace; casting technology; ceramic probe; conservation parameter method; corroding prevention; cubage compensation method; dose precision; electromagnetic pump work; feed current; feed liquid technology; fixed metal probe; fixed suspended height method; hydrogen content; molten aluminum alloy; oxidation impurity content; power stability; predetermined dose irrigating system; removable metal probe; Aluminum alloys; Electromagnetics; Feeds; Magnetic liquids; Probes; Aluminum Alloy; Electromagnetic Pump; Predetermined Dose Irrigating Precision; Predetermined Dose Irrigating System; Removable Probe;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Application and System Modeling (ICCASM), 2010 International Conference on
  • Conference_Location
    Taiyuan
  • Print_ISBN
    978-1-4244-7235-2
  • Type

    conf

  • DOI
    10.1109/ICCASM.2010.5622714
  • Filename
    5622714