DocumentCode
534479
Title
One novel composite nano-particles membrane modified amperometric immunosensor for Escherichia coli in polluted waters
Author
Wu, Yuanzhao ; Hu, Futao ; Gan, Ning ; Li, Tianhua ; Gao, Lijuan
Author_Institution
Fac. of Mater. Sci. & Chem. Eng., Ningbo Univ., Ningbo, China
Volume
4
fYear
2010
fDate
16-18 Oct. 2010
Firstpage
1540
Lastpage
1543
Abstract
A novel amperometric immunoassay for identification of Escherichia coli (E.coli) in a matrix containing zirconium dioxide nanoparticles (ZrO2) was described. Firstly, the antibody of E.coli (anti E.coli) was immobilized on a glassy carbon electrode (GCE) modified with carbon nanotubes (CNTs) using ZrO2 nanoparticles, colloidal gold (Au) and poly-Lysine (pLL) composite membrane (ZrO2-Au-pLL-anti-E.coli) aiming to maintain the antibody´s bioactivity. Then one novel sebacato-bridged Co(□) complex Co(suc)(bpy)(H2O)2 (referred to as CoL, suc=succinic acid; bpy=2,2´-bipyridine) was adsorbed onto the surface of ZrO2-Au-pLL-anti-E.coli composite membrane, thus the immunosensor (GCE|CNTs|ZrO2-Au-pLL-anti-E.coli|CoL) for determination of E.coli was constructed based on one step immunoreaction using cyclic voltammetry (CV) method. CoL can be employed as an electron transfer mediator for catalytic activity detection of H2O2. After the immunosensor was incubated with E.coli solution at room temperature for 20 min, the electron transfer access of CoL to H2O2 was partly inhibited, which leads to a linear decrease of the catalytic efficiency to H2O2. The immunosensor was employed to determine E.coli in samples and the results were consistent to the tradition enzyme-linked immunosorbent assays (ELISA) method. The proposed ampero metric immunosensor was sensitive, quick and disposable, which was suitable for determination of E.coli in polluted waters for public health and environmental protection.
Keywords
amperometric sensors; biosensors; microorganisms; nanocomposites; nanoparticles; voltammetry (chemical analysis); water pollution measurement; zirconium compounds; ELISA method; Escherichia coli; amperometric immunosensor; antibody bioactivity; composite nanoparticle membrane; cyclic voltammetry; enzyme linked immunosorbent assays; glassy carbon electrode; polluted water; zirconium dioxide; Biomembranes; Biosensors; Electric potential; Electrodes; Immune system; Nanoparticles; Surface morphology; Amperometric Immunosensor; Co(suc)(bpy)(H2 O)2 ; E.coli; ZrO2 -Au-poly-Lysine nano-membrane;
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical Engineering and Informatics (BMEI), 2010 3rd International Conference on
Conference_Location
Yantai
Print_ISBN
978-1-4244-6495-1
Type
conf
DOI
10.1109/BMEI.2010.5639388
Filename
5639388
Link To Document