Analysis on performance characteristics of alternator system considering load conditions and power factor
Author :
Jang, Seok-Myeong ; Park, Yu-Seop ; Ko, Kyoung-Jin ; Choi, Jang-Young ; You, Dae-Joon ; Goo, Cheol-Soo
Author_Institution :
Dept. of Electr. Eng., Chungnam Nat´´l Univ., Daejeon, South Korea
fYear :
2010
fDate :
10-13 Oct. 2010
Firstpage :
1434
Lastpage :
1437
Abstract :
This paper presents the characteristic analysis on the high speed synchronous generator considering load conditions and power factor. The generator consists of the rotor with the short-circuited field coils connected to armature coils of an exciter and a stator with three-phase winding. To analyze the characteristics considering load conditions, the equivalent circuit method considering the effects of saliency and Finite Element Method (FEM) are applied.
Keywords :
alternators; equivalent circuits; finite element analysis; load (electric); power factor; rotors; stators; FEM; alternator system; armature coil; equivalent circuit method; finite element method; high speed synchronous generator; load condition; performance analysis; power factor; rotor; short-circuited field coil; stator; three-phase winding; Air gaps; Finite element methods; Reactive power; Synchronous generators; Voltage control; Windings;