• DocumentCode
    541515
  • Title

    Comparison of aortic lumen area and distensibility using cine and phase contrast acquisitions

  • Author

    Herment, A. ; Lefort, M. ; De Cesare, A. ; Kachenoura, N. ; Frouin, F. ; Mousseaux, E.

  • Author_Institution
    UMRS, UPMC-Inserm, Paris, France
  • fYear
    2010
  • fDate
    26-29 Sept. 2010
  • Firstpage
    173
  • Lastpage
    176
  • Abstract
    The accuracy of the estimation of the aortic lumen area was investigated using an automated segmentation method (ART-FUN). The study included both Steady State Free Precession (SSFP) and Phase Contrast (PC) MR acquisition sequences. The precision of the segmented lumen area was tested against expert manual contouring for 860 aorta sections from three different MR scanners. Comparison of lumen areas and distensibility values obtained from both SSFP and PC sequences was also performed in a group of 50 subjects. While linear regressions indicated very similar manual and automated segmentations for SSFP and PC data (slope=1, r=0.99), the corresponding distensibility values were less correlated (slope=0.76, r=0.54).
  • Keywords
    biomedical MRI; blood vessels; image segmentation; medical image processing; regression analysis; spatial variables measurement; ART-FUN; SSFP MR acquisition sequence; aortic lumen area estimation accuracy; automated segmentation method; distensibility; linear regressions; phase contrast MR acquisition sequence; steady state free precession; Accuracy; Biomedical imaging; Estimation; Image segmentation; Magnetic resonance imaging; Manuals;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology, 2010
  • Conference_Location
    Belfast
  • ISSN
    0276-6547
  • Print_ISBN
    978-1-4244-7318-2
  • Type

    conf

  • Filename
    5737937