  • Abstract
    The purpose of this study was to find out differences between septicemic and healthy premature newborns from the respiratory signal. An statistical analysis of breathing trace´s temporal features showed significant differences between the inspiration/expiration ratio, being its average value shorter in healthy patients. All patient´s total respiratory cycle time exceeding the apnea threshold were classified, and two different distributions had been found: log-normal for non septicemic and GEV (Generalized Extreme Value) distribution for septicemic. Finally, assessing fractal signal properties, we found an increased Hurst exponent (H) in non infected population. Results suggest that respiratory parameters could be helpful in sepsis diagnosis together with heart rate variability (HRV), demonstrated a relevant marker by our research team.
  • Keywords
    diseases; electrocardiography; medical signal processing; paediatrics; patient diagnosis; pneumodynamics; signal classification; statistical analysis; Hurst exponent; apnea threshold; breathing; diagnostic tool; expiration; fractal signal properties; generalized extreme value; heart rate variability; inspiration; late onset sepsis; premature newborns; respiration signal; statistical analysis; total respiratory cycle time; Cardiology; Fractals; Heart rate variability; Maximum likelihood estimation; Pediatrics; Statistical analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology, 2010
  • Conference_Location
    Belfast
  • ISSN
    0276-6547
  • Print_ISBN
    978-1-4244-7318-2
  • Type

    conf

  • Filename
    5738131