DocumentCode
541696
Title
Respiration signal as a promising diagnostic tool for late onset sepsis in premature newborns
Author
Navarro, X. ; Porée, F. ; Beuchée, A. ; Carrault, G.
Author_Institution
LTSI, Univ. de Rennes 1, Rennes, France
fYear
2010
fDate
26-29 Sept. 2010
Firstpage
947
Lastpage
950
Abstract
The purpose of this study was to find out differences between septicemic and healthy premature newborns from the respiratory signal. An statistical analysis of breathing trace´s temporal features showed significant differences between the inspiration/expiration ratio, being its average value shorter in healthy patients. All patient´s total respiratory cycle time exceeding the apnea threshold were classified, and two different distributions had been found: log-normal for non septicemic and GEV (Generalized Extreme Value) distribution for septicemic. Finally, assessing fractal signal properties, we found an increased Hurst exponent (H) in non infected population. Results suggest that respiratory parameters could be helpful in sepsis diagnosis together with heart rate variability (HRV), demonstrated a relevant marker by our research team.
Keywords
diseases; electrocardiography; medical signal processing; paediatrics; patient diagnosis; pneumodynamics; signal classification; statistical analysis; Hurst exponent; apnea threshold; breathing; diagnostic tool; expiration; fractal signal properties; generalized extreme value; heart rate variability; inspiration; late onset sepsis; premature newborns; respiration signal; statistical analysis; total respiratory cycle time; Cardiology; Fractals; Heart rate variability; Maximum likelihood estimation; Pediatrics; Statistical analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Computing in Cardiology, 2010
Conference_Location
Belfast
ISSN
0276-6547
Print_ISBN
978-1-4244-7318-2
Type
conf
Filename
5738131