DocumentCode :
544156
Title :
Suppression of power level fluctuations at leaky coaxial cable ends using ferrite cores
Author :
Engelbrecht, Julia ; Collmann, Ralf ; Birkel, Ulrich ; Weber, Mark
Author_Institution :
Dept. of Electr. Eng., HTW Dresden, Dresden, Germany
fYear :
2011
fDate :
14-16 March 2011
Firstpage :
1
Lastpage :
4
Abstract :
Leaky coaxial cables are not only used for radio coverage but also for indoor positioning and navigation. For positioning with RF fingerprinting the received signal power levels at various positions are measured and stored in a radio map. The accuracy of this positioning method strongly depends on the reliability of the radio map. Therefore, the power level fluctuations have to be suppressed, to get a higher localization accuracy. With approaches like averaging the measured power levels by frequency, time, place and antenna polarization some improvement was achieved, but the reachable indoor positioning accuracy could not be used for practical application. In this paper constructive approaches are investigated to suppress power level fluctuations by using ferrite cores and variations of slot apertures.
Keywords :
coaxial cables; iron compounds; position control; RF fingerprinting; ferrite cores; leaky coaxial cable ends; positioning; power level fluctuations; received signal power levels; Antenna measurements; Cable shielding; Coaxial cables; Couplings; Ferrites; Loss measurement; Power cables; Coaxial transmission lines; electromagnetic coupling; indoor radio communication;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference (GeMIC), 2011 German
Conference_Location :
Darmstadt
Print_ISBN :
978-1-4244-9225-1
Electronic_ISBN :
978-3-9812668-3-2
Type :
conf
Filename :
5760766
Link To Document :