Title :
A boundary element model of electrodes inserted in orthotropic muscle
Author :
Henneberg, Kaj-Åge
Author_Institution :
Institute de génie biomédical, Université de Montréal P.O. Box 6128, Station A, Montréal, Québec, Canada, H3C 3J7
fDate :
Oct. 29 1992-Nov. 1 1992
Abstract :
This paper describes a method for modelling electrodes inserted in orthotropic tissue. First a boundary element formulation for orthotropic tissue is described and then a node condensation technique is employed that allows the system matrix to be solved with an iterative solver.
Conference_Titel :
Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE
Conference_Location :
Paris, France
Print_ISBN :
0-7803-0785-2
Electronic_ISBN :
0-7803-0816-6
DOI :
10.1109/IEMBS.1992.5761399