A PC based large finite difference thoracic model for determining current pathways from external voltage or current sources
Author :
Patterson, Robert ; Wang, Li
Author_Institution :
University of Minnesota UMHC Box 297, Minneapolis, MN 55455
Volume :
6
fYear :
1992
fDate :
Oct. 29 1992-Nov. 1 1992
Firstpage :
2340
Lastpage :
2341
Abstract :
A 520K element finite difference model of the thorax was developed from ECG gated MRIs. A C++ computer program was developed and run on an IBM compatible 486–40 MHz computer that takes 22.5 hours for 250 iterations. This converges to an impedance values within 04% of the value obtained in 500 iterations. This development demonstrates the successful use of a PC to solve large finite difference problems.