• DocumentCode
    547933
  • Title

    Analysis and simulation of LCL resonant inverter for low cold resistance application

  • Author

    Shafiei, Navid ; Farzanehfard, Hosein ; Motahari, S.R. ; Mesgarzadeh, H.R.

  • Author_Institution
    Inf. & Commun. Technol. Inst., Isfahan Univ. of Technol., Isfahan, Iran
  • fYear
    2011
  • fDate
    17-19 May 2011
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    In This paper, the steady state analysis of a 3rd order LCL resonant inverter is presented. The analysis of mathematical model shows that this topology has the capability of inherent over current protection. In addition, the inverter switches current stay in nominal value. This is suitable for low cold resistance which needs to limit the current at start-up condition. The simulation results verify the accuracy and validity of model and its performance in the mentioned usage.
  • Keywords
    harmonic analysis; overcurrent protection; resonant invertors; FHA technique; first harmonic approximation; low cold resistance application; mathematical model; over current protection; steady state analysis; third order LCL resonant inverter simulation; 3rd order LCL resonant inverter; First Harmonic Approximation (FHA); Low cold resistance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Engineering (ICEE), 2011 19th Iranian Conference on
  • Conference_Location
    Tehran
  • Print_ISBN
    978-1-4577-0730-8
  • Type

    conf

  • Filename
    5955823