DocumentCode :
547933
Title :
Analysis and simulation of LCL resonant inverter for low cold resistance application
Author :
Shafiei, Navid ; Farzanehfard, Hosein ; Motahari, S.R. ; Mesgarzadeh, H.R.
Author_Institution :
Inf. & Commun. Technol. Inst., Isfahan Univ. of Technol., Isfahan, Iran
fYear :
2011
fDate :
17-19 May 2011
Firstpage :
1
Lastpage :
1
Abstract :
In This paper, the steady state analysis of a 3rd order LCL resonant inverter is presented. The analysis of mathematical model shows that this topology has the capability of inherent over current protection. In addition, the inverter switches current stay in nominal value. This is suitable for low cold resistance which needs to limit the current at start-up condition. The simulation results verify the accuracy and validity of model and its performance in the mentioned usage.
Keywords :
harmonic analysis; overcurrent protection; resonant invertors; FHA technique; first harmonic approximation; low cold resistance application; mathematical model; over current protection; steady state analysis; third order LCL resonant inverter simulation; 3rd order LCL resonant inverter; First Harmonic Approximation (FHA); Low cold resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Engineering (ICEE), 2011 19th Iranian Conference on
Conference_Location :
Tehran
Print_ISBN :
978-1-4577-0730-8
Type :
conf
Filename :
5955823
Link To Document :
بازگشت