  • Abstract
    Based on a low-cost micro-machined infrared (IR) source with subsequent gas specific filter, photoacoustic absorption (PA) measurements were investigated in a nonresonant operating mode of a gas cell. In addition, nondispersive IR (NDIR) transmission measurements based on a thermopile detector were used to expand the measurement range, but also for an inherent self-monitoring scheme of the system. Compared to other systems using expensive laser sources for stimulation of acoustic pressure waves in a resonant mode of operation, the approach is based on low-cost components. The IR source was modulated in the frequency range between 1 and 10 Hz. To achieve enhanced resolution and a good signal to noise ratio the sensor raw data-both for transmission as well as absorption measurements-were evaluated using discrete Fourier transformation. By combining PA and NDIR transmission measurements a wide concentration range is achieved, e.g., 100-20 000 ppm of carbon dioxide for a measurement cell with a length of 9 cm. Whereas the NDIR transmission measurement is suitable for monitoring higher concentrations, the PA measurement offers better detectivity at lower gas concentrations. Furthermore, the modular system allows the realization of a self-monitoring scheme by comparing the signals measured with both approaches, thus omitting the need for a second filter at a reference wavelength.
  • Keywords
    gas sensors; infrared detectors; thermopiles; NDIR transmission; gas cell; low-cost micromachined infrared source; nondispersive IR transmission measurements; nonresonant operating mode; photoacoustic absorption measurements; subsequent gas specific filter; thermopile detector; versatile gas detection system; Absorption; Acoustic measurements; Calibration; Discrete Fourier transforms; Frequency modulation; Wavelength measurement; Nondispersive infrared measurement; photoacoustic absorption measurement; self-monitoring; versatile gas detection system;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2012.2224104
  • Filename
    6329389