• DocumentCode
    549923
  • Title

    Update on partial discharge screening tests for stator bars & coils

  • Author

    McDermid, W. ; Bromley, J.C. ; Black, T.

  • Author_Institution
    Manitoba Hydro, Winnipeg, MB, Canada
  • fYear
    2011
  • fDate
    5-8 June 2011
  • Firstpage
    20
  • Lastpage
    22
  • Abstract
    In 1992 a paper examined evidence of a relationship between measured partial discharge and subsequent voltage endurance of certain stator bars. The PD test method utilizes a higher frequency range than the conventional 30 kHz to 400 kHz and may be more appropriate for the detection of internal voids. More recently there have been other instances where these PD measurements have been useful for identifying stator bars or coils which may have short times to failure on voltage endurance. This paper updates the evidence.
  • Keywords
    bars; coils; partial discharge measurement; stators; coils; measured partial discharge; partial discharge screening tests; stator bars; Bars; Coils; Partial discharge measurement; Partial discharges; Stator bars; Voltage measurement; Windings; partial discharge; rotating machines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference (EIC), 2011
  • Conference_Location
    Annapolis, MD
  • ISSN
    pending
  • Print_ISBN
    978-1-4577-0278-5
  • Electronic_ISBN
    pending
  • Type

    conf

  • DOI
    10.1109/EIC.2011.5996107
  • Filename
    5996107