  • Title

    Incipient fault detection in 33/11kV power transformers by using combined Dissolved Gas Analysis technique and acoustic partial discharge measurement and validated through untanking

  • Author

    Samsudin, Mohd Raffi ; Ramli, Ahmad Qisti ; Berhanuddin, Ahmad ; Yang, Young Zaidey

  • Author_Institution
    High Voltage Diagnostics, TNB Res. Sdn Bhd, Kajang, Malaysia
  • fYear
    2010
  • fDate
    20-22 Sept. 2010
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Power transformer consists of components which are under consistent thermal and electrical stresses. The major component which degrades under these stresses is the paper insulation of the power transformer. The electrical fault can develop into thermal fault such as localized insulation burning or hot-spots. Any fault in the transformer can be detected by using Dissolved Gas Analysis technique. In this paper, the detection of electrical and thermal faults in 14 units of 33/11kV, 30 MVA and 15MVA transformers were done by using Dissolved Gas Analysis (DGA). Then, the acoustic partial discharge test was carried out to detect the activity and locate the source of the electrical fault. All the transformers were untanked and the inspection was done. From the inspection done, there were a few incipient faults detected such as overheating due to loose connection, sharp edges, insulation burning, choking effect due to moisture and surface tracking in On-Load Tap Changer (OLTC) compartment. As a conclusion, the combination of the acoustic partial discharge technique and DGA technique have proved to be a useful tool in detecting and locating incipient faults in the power transformer.
  • Keywords
    acoustic measurement; chemical analysis; fault diagnosis; on load tap changers; partial discharge measurement; DGA technique; OLTC compartment; acoustic partial discharge measurement; acoustic partial discharge test; apparent power 15 MVA; apparent power 30 MVA; choking effect; combined dissolved gas analysis technique; electrical fault; electrical stress; incipient fault detection; insulation burning; on-load tap changer compartment; paper insulation; power transformers; surface tracking; thermal fault; thermal stress; voltage 11 kV; voltage 33 kV; Acoustics; Oil insulation; Partial discharges; Power transformer insulation; Sensors; Arcing; Dissolved Gas Analysis; On Load Tap Changer (OLTC); Partial Discharge;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Modern Electric Power Systems (MEPS), 2010 Proceedings of the International Symposium
  • Conference_Location
    Wroclaw
  • Print_ISBN
    978-83-921315-7-1
  • Type

    conf

  • Filename
    6007229