• DocumentCode
    551934
  • Title

    A study on the selection of operating parameters to monitor steam turbine generator in a Korea Standard Type Nuclear Power Plant

  • Author

    Choi, I.K. ; Kim, J.A. ; Woo, J.H. ; Byun, S.H. ; Yang, K.H.

  • Author_Institution
    KEPCCO Res. Inst., Daejeon, South Korea
  • fYear
    2011
  • fDate
    16-18 Aug. 2011
  • Firstpage
    169
  • Lastpage
    172
  • Abstract
    This paper contains the selection of operation parameters to monitor both steam turbine and generator in a Korea Standard Type Nuclear Power Plant. The nuclear reactor must be monitored for its safe operation. Additionally the seam turbine and generator, two important machines in nuclear power plant, must be monitored for its safe operation also. For the purpose of this, we describe here how the operating parameters were selected, reviewed, implemented into the operator console and finally put into actual operation of the power plant.
  • Keywords
    nuclear power stations; steam turbines; turbogenerators; Korea standard type nuclear power plant; nuclear reactor; operating parameters; steam turbine generator monitoring; Cooling; Generators; Monitoring; Turbines; Valves; Vibrations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Interaction Sciences (ICIS), 2011 4th International Conference on
  • Conference_Location
    Busan
  • Print_ISBN
    978-1-4577-0480-2
  • Electronic_ISBN
    978-89-88678-45-9
  • Type

    conf

  • Filename
    6014552