DocumentCode
551934
Title
A study on the selection of operating parameters to monitor steam turbine generator in a Korea Standard Type Nuclear Power Plant
Author
Choi, I.K. ; Kim, J.A. ; Woo, J.H. ; Byun, S.H. ; Yang, K.H.
Author_Institution
KEPCCO Res. Inst., Daejeon, South Korea
fYear
2011
fDate
16-18 Aug. 2011
Firstpage
169
Lastpage
172
Abstract
This paper contains the selection of operation parameters to monitor both steam turbine and generator in a Korea Standard Type Nuclear Power Plant. The nuclear reactor must be monitored for its safe operation. Additionally the seam turbine and generator, two important machines in nuclear power plant, must be monitored for its safe operation also. For the purpose of this, we describe here how the operating parameters were selected, reviewed, implemented into the operator console and finally put into actual operation of the power plant.
Keywords
nuclear power stations; steam turbines; turbogenerators; Korea standard type nuclear power plant; nuclear reactor; operating parameters; steam turbine generator monitoring; Cooling; Generators; Monitoring; Turbines; Valves; Vibrations;