Abstract :
A simple OCT (optical coherence tomography) scheme based on a 4×4 fiber coupler is proposed for the simultaneous measurement of the refractive index and the thickness of optical samples. It used the optical path length difference of interference light to calculate the refractive index and the thickness of the unknown sample.
Keywords :
fibre optic sensors; light interference; optical fibre couplers; optical tomography; refractive index measurement; thickness measurement; fiber coupler; group refractive index measurement; interference light; optical coherence tomography; optical path length difference; sample thickness measurement; Optical refraction; Tomography;