Abstract :
Modern trains with active line-side converters are currently the state-of-the-art technology in the traction industry. In such systems, the active line-side converter of the drive system can be exploited for power quality improvement purposes. In this paper, adopting the active line-side converter, an identification strategy is proposed, which estimates the parameters of the catenary line through the injection of low-order harmonic current and monitoring the corresponding voltage at the connection point of the pantograph to the network.
Keywords :
parameter estimation; power conversion harmonics; power supply quality; railway electrification; traction; active line-side converters; harmonic current injection; identification strategy; low-order harmonic current; parameter estimation; power quality improvement; railway catenary parameters identification; traction industry; voltage monitoring; Current control; Frequency control; Harmonic analysis; Inductance; Power harmonic filters; Resistance; Resonant frequency; Active Front-End; Converter control; Electric locomotives; Rail vehicle; Voltage Source Converter;