• DocumentCode
    553599
  • Title

    A simple calorimetric setup for the accurate measurement of losses in power electronic converters

  • Author

    Dimitrakakis, G.S. ; Tatakis, E.C. ; Nanakos, Anastasios Ch.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Patras, Patras, Greece
  • fYear
    2011
  • fDate
    Aug. 30 2011-Sept. 1 2011
  • Firstpage
    1
  • Lastpage
    9
  • Abstract
    This paper deals with the analysis and implementation of a low cost calorimetric setup, suitable for loss measurements in power electronic converters, for power ratings up to 30W. Main component of the device is an open Dewar vessel. A proper calibration method is suggested and the several error factors are spotted, so as to achieve an overall accuracy of 2%. Application examples are demonstrated with loss measurements on magnetic components.
  • Keywords
    calibration; calorimetry; loss measurement; power convertors; calorimetric setup; loss measurement; magnetic components; open Dewar vessel; power 30 W; power electronic converters; Calibration; Fasteners; Loss measurement; Temperature distribution; Temperature measurement; Thermistors; Voltage measurement; Measurement; efficiency; magnetic component; sensor; user application experience;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE 2011), Proceedings of the 2011-14th European Conference on
  • Conference_Location
    Birmingham
  • Print_ISBN
    978-1-61284-167-0
  • Electronic_ISBN
    978-90-75815-15-3
  • Type

    conf

  • Filename
    6020458