• DocumentCode
    553704
  • Title

    Contactless power supply system with resonant circuit parameter change compensation

  • Author

    Kalisiak, S. ; Marcinek, M. ; Holub, Michal ; Palka, R.

  • Author_Institution
    Dept. OF Electr. Eng., WEST POMERANIAN Univ. OF Technol., Szczecin, Poland
  • fYear
    2011
  • fDate
    Aug. 30 2011-Sept. 1 2011
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    Contactless power supply systems are of high interest in all small power and large power applications. Many high efficiency systems use the resonant operation mode. A parallel compensation system is presented enlarging overall system safety and allowing for resonant system parameter change while maintaining ZCS operation. Simulation and experimental results are given allowing for system justification and resonant parameter change influence and compensation capabilities are presented. Systems performance allows for large parameter drift and increases the overall efficiency in case of large parameter variation. An increase of 3, 5% was measured in the case of investigated prototype.
  • Keywords
    zero current switching; ZCS operation; contactless power supply system; large power applications; parallel compensation system; resonant circuit parameter change compensation; resonant operation mode; resonant system parameter change; small power applications; zero current switching; Delay; Inductors; Power supplies; RLC circuits; Resonant frequency; Zero current switching; Contactless Power Supply; High frequency power converter; Power transmission; Wireless power transmission; ZCS converters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE 2011), Proceedings of the 2011-14th European Conference on
  • Conference_Location
    Birmingham
  • Print_ISBN
    978-1-61284-167-0
  • Electronic_ISBN
    978-90-75815-15-3
  • Type

    conf

  • Filename
    6020563