DocumentCode
553704
Title
Contactless power supply system with resonant circuit parameter change compensation
Author
Kalisiak, S. ; Marcinek, M. ; Holub, Michal ; Palka, R.
Author_Institution
Dept. OF Electr. Eng., WEST POMERANIAN Univ. OF Technol., Szczecin, Poland
fYear
2011
fDate
Aug. 30 2011-Sept. 1 2011
Firstpage
1
Lastpage
8
Abstract
Contactless power supply systems are of high interest in all small power and large power applications. Many high efficiency systems use the resonant operation mode. A parallel compensation system is presented enlarging overall system safety and allowing for resonant system parameter change while maintaining ZCS operation. Simulation and experimental results are given allowing for system justification and resonant parameter change influence and compensation capabilities are presented. Systems performance allows for large parameter drift and increases the overall efficiency in case of large parameter variation. An increase of 3, 5% was measured in the case of investigated prototype.
Keywords
zero current switching; ZCS operation; contactless power supply system; large power applications; parallel compensation system; resonant circuit parameter change compensation; resonant operation mode; resonant system parameter change; small power applications; zero current switching; Delay; Inductors; Power supplies; RLC circuits; Resonant frequency; Zero current switching; Contactless Power Supply; High frequency power converter; Power transmission; Wireless power transmission; ZCS converters;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Applications (EPE 2011), Proceedings of the 2011-14th European Conference on
Conference_Location
Birmingham
Print_ISBN
978-1-61284-167-0
Electronic_ISBN
978-90-75815-15-3
Type
conf
Filename
6020563
Link To Document