DocumentCode :
554733
Title :
Study on the critical cathode-mesh electric field for designing a streak image tube
Author :
Xin Bai ; Hua Liao ; Han-Ben Niu
Author_Institution :
Inst. of Optoelectron., Shenzhen Univ., Shenzhen, China
Volume :
7
fYear :
2011
fDate :
12-14 Aug. 2011
Firstpage :
3502
Lastpage :
3504
Abstract :
The influences of cathode-mesh electric field on a streak image tube were studied in this paper. The results show that a critical field value following the pulse current density exists. The temporal resolution of the image tube can significantly be improved by increasing the electric field when the field strength less than the critical value, but if the field is greater, it lacks influence on the temporal resolution. Under the conditions of current density 20A/cm2, the critical electric field is 10kV/mm. It is significance for designing the streak image tube.
Keywords :
cathodes; current density; streak cameras; critical cathode-mesh electric field; critical electric field; field strength; pulse current density; streak image tube; temporal resolution; Cathodes; Dispersion; Electric fields; Electron tubes; Image resolution; Lenses; Space charge; X-ray; image tube; temporal resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronic and Mechanical Engineering and Information Technology (EMEIT), 2011 International Conference on
Conference_Location :
Harbin, Heilongjiang
Print_ISBN :
978-1-61284-087-1
Type :
conf
DOI :
10.1109/EMEIT.2011.6023779
Filename :
6023779
Link To Document :
بازگشت