  • Title

    A qualification system for high temperature sterilization

  • Author

    Qiuting Jia ; Guizhen Wang ; Jinyong Cheng

  • Author_Institution
    Sch. of Sci., Shandong Polytech. Univ., Jinan, China
  • Volume
    8
  • fYear
    2011
  • fDate
    12-14 Aug. 2011
  • Firstpage
    4106
  • Lastpage
    4109
  • Abstract
    It is very necessary to verify the efficiency of the high temperature sterilization which is a very important process in the production of medicament especially for injections. This paper describes a system named QT-3000 which is a qualification system for the high temperature sterilization. During a qualification, the sensor readings, interval calculations, statistical calculations, the instantaneous and accumulate lethality results are displayed on the touch screen and uploaded to a host computer for further analysis.
  • Keywords
    computerised instrumentation; drugs; pharmaceutical industry; production engineering computing; sensors; statistical analysis; sterilisation (microbiological); touch sensitive screens; QT-3000 qualification system; high temperature sterilization; injection production; interval calculation; medicament production; sensor readings; statistical calculation; touch screen display; Calibration; Computers; Microcontrollers; Microorganisms; Monitoring; Qualifications; Temperature sensors; high temperature; lethality; qualification; sterilization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic and Mechanical Engineering and Information Technology (EMEIT), 2011 International Conference on
  • Conference_Location
    Harbin, Heilongjiang
  • Print_ISBN
    978-1-61284-087-1
  • Type

    conf

  • DOI
    10.1109/EMEIT.2011.6023956