• DocumentCode
    556077
  • Title

    Expanding the frequeny range for DPI testing of IC´s above 1 GHz: An alternative proposal

  • Author

    Catrysse, Johan ; Pissoort, Davy ; Vanhee, Filip

  • Author_Institution
    MICAS, KHBO - KULeuven Assoc., Oostende, Belgium
  • fYear
    2011
  • fDate
    26-30 Sept. 2011
  • Firstpage
    400
  • Lastpage
    404
  • Abstract
    Characterizing Integrated Circuits (IC´s) against immunity may be done in different ways, as defined in the set of standards EN IEC 62132-x. Especially, the subpart EN IEC 62132-4 defines a test setup called Direct RF Power Injection method (DPI) and is specified for the frequency range from 150 kHz up to 1 GHz. Although it is a well defined measuring method, problems are occurring above 10 MHz in order to estimate the right immunity level of the IC under test. In more, it should be of great interest to have the method available above the frequency limit of 1 GHz. In this paper, a test setup is proposed to overcome both requirements.
  • Keywords
    IEC standards; integrated circuit testing; DPI testing; EN IEC 62132-x; IC; direct RF power injection method; frequency 150 kHz to 1 GHz; integrated circuits; Capacitors; Directional couplers; Immunity testing; Integrated circuits; Strips; Transmission line measurements; DPI; IC´s; immunity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    EMC Europe 2011 York
  • Conference_Location
    York
  • Print_ISBN
    978-1-4577-1709-3
  • Type

    conf

  • Filename
    6078593