DocumentCode :
556127
Title :
Measurement of longitudinal conversion loss (LCL) in semianechoic chambers from 150kHz to 300MHz
Author :
Pascagaza, John F Hernández ; Martín, Delia Heras
Author_Institution :
Electromagn. Compatibility Lab., ATP &TA, Valencia, Spain
fYear :
2011
fDate :
26-30 Sept. 2011
Firstpage :
240
Lastpage :
244
Abstract :
Several LCL measurements were carried out in the powerline sockets of three semianechoic chambers with the aim at characterizing and analyzing their possible influence in radiated and conducted emission tests. For this purpose the coupling instrument to characterize LCL measurement was built and calibrated. The test method was developed, validated and LCL measurements were carried out from 150KHz to 300MHz. Disparate LCL values were obtained of each semianechoic chamber.
Keywords :
anechoic chambers (electromagnetic); electric connectors; electromagnetic wave propagation; LCL measurements; conducted emission tests; coupling instrument; frequency 150 kHz to 300 MHz; longitudinal conversion loss; powerline sockets; radiated emission tests; semianechoic chambers; Electromagnetic compatibility; Frequency measurement; Impedance; Loss measurement; Probes; Transmission line measurements; Voltage measurement; Longitudinal Conversion Loss (LCL); Macfarlane probe; radiated and conducted emmision test; semianechoic chamber;