• DocumentCode
    558431
  • Title

    Preliminary statistical study of low voltage distribution feeders under a representative HV network in Western Australia

  • Author

    Li, Yingliang ; Wolfs, Peter

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Curtin Univ. of Technol., Perth, WA, Australia
  • fYear
    2011
  • fDate
    25-28 Sept. 2011
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    This paper presents a preliminary clustering analysis study on a set of LV feeders connected to a selected prototypical HV feeder that represents the light suburban residential class in Western Australian. The study led to the identification of several subsets of LV feeders where each represents specific types of users. The intended use of the LV feeder cluster data is to develop representative test case LV feeders. These can be applied in the impact assessment of technology change including Smart Grid deployments or load changes due to solar panel, air conditioning or electric vehicle uptake. The work will be expanded to include LV feeder cluster analysis for networks supplied from other HV feeder types.
  • Keywords
    distribution networks; smart power grids; statistical analysis; LV feeders; Western Australia; air conditioning; electric vehicle; low voltage distribution feeders; representative HV network; smart grid; solar panel; Clustering methods; Databases; Energy consumption; Load modeling; Niobium; Road transportation; Smart grids;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Universities Power Engineering Conference (AUPEC), 2011 21st Australasian
  • Conference_Location
    Brisbane, QLD
  • Print_ISBN
    978-1-4577-1793-2
  • Type

    conf

  • Filename
    6102562